- Contact Person : Ms. Peng Agnes
- Company Name : Shanghai Cixi Instrument Co., Ltd.
- Tel : 86-21-5763 2436
- Fax : 86-21-5763 4942
- Address : Shanghai,Shanghai,Rm613, Jiahe Sunny Plaza, No.76 JiuTing Road, Songjiang District, Shanghai, P.R. China.
- Country/Region : China
- Zip : 201615
Related Product Searches:Open channel Ultrasonic flowmeter(flow meter),High Quality Open channel Ultrasonic flowmeter,Open channel Ultrasonic flowmeter XMH-DM
Open channel Ultrasonic flowmeter
Application :
Aqueduct
Wastewater treatment
Features:
High precise
Selectable output mode
Strong anti-interference
Automatic temperature compensation
Specification:
Full scale: 10L/S~10m3/S
Unusable area: ≤0.3m
Accumulative flow range: 99999999 (up to 8 figures auto-zero recalculate)
Display content: liquid level, momentary flow, accumulative flow
Probe level: 0.3-5.0m
Probe frequency: 20 K-43 KHz
Measurement resolution: ±0.25% X full scale
Display resolution: 1mm
Probe display: 4 figure Nixie
Equipment setting: 3 sensitive key
Power: AC 220V
Output signal: RS485 (other output signal is available)
Dimension: Φ75mm×M48mm×110mm
Material: ABS plastic for cover; PP for transducer
Fix model: out straight screw M50×1.5
Admission cable: 1.5m
Protection degree: IP65
Ambient pressure: normal condition
Temperature: 0°C~50°C for work , -40°C~85°C for storage
Humidity : ≤80% Non-Condensing for work, ≤70% Non-Condensing for storage
Note: preparation
Rectangular weir: 1~4%
Triangular weir: 1~2%
Parshall flume: 3%